Choose FD30 for domestic flat entrances, internal cupboard and riser enclosure doors, and low-rise stair enclosures up to 11 metres. Choose FD60 for protected stairwells in medium- and high-rise buildings, compartment boundaries adjacent to high-risk service rooms, and vertical escape cores carrying heavy occupant loads. The rating your project requires comes down to three variables: building height, occupancy type, and the compartment-boundary classification established by your governing building code.
FD30 vs FD60 Fire Doors — Key Differences & Buying Guide
The main difference between FD30 and FD60 fire doors is the duration of fire resistance each assembly is engineered to withstand: an FD30 doorset provides 30 minutes of tested fire integrity and insulation, while an FD60 provides 60 minutes. That extra half-hour comes from structural and material changes—not simply a thicker slab—and it determines which building openings each rating can safely serve.
Both are door assemblies measured against the same test standard (BS EN 1634-1), but the design intent diverges sharply once you map them to room function and compartmentation strategy. Understanding where each fits in your project is what separates compliant specifications from costly mistakes after installation.
Definitions: What Do FD30 and FD60 Actually Mean?

In UK building terminology, “FD” stands for Fire Door, and the number indicates the fire-resistance period measured in minutes under standardized conditions. This applies to the complete fire door assembly—door leaf, frame, seals, and specified hardware—not just the bare leaf.
An FD30 assembly must maintain integrity (no flame or hot-gas passage) and insulation (surface temperature on the unexposed side does not exceed defined limits) for at least 30 minutes during the BS EN 1634-1 test cycle. An FD60 must sustain both for 60 minutes under identical conditions.
It matters that the rating covers the full fire door set. A 30-minute certified leaf fitted into an uncertified frame, or sealed with incorrect intumescent strips, may not perform to its published rating once installed. Buyers evaluating suppliers should always confirm that the supplied item carries third-party scheme affiliation such as FIRASS or BM TRADA, which verifies the complete tested assembly—not just the leaf alone.
See our EI30 vs EI60 vs EI90 comparison guide for context on the broader European fire-rating nomenclature that sometimes appears alongside FD labels in project documentation.
Core Construction: What Actually Creates the Time Difference?
The jump from 30 to 60 minutes is not linear. It requires deliberate changes across core density, reinforcement, and seal integration:
What’s inside an FD30?
Most residential and light-commercial FD30 doors use a mineral core sandwiched between steel or timber skins. Steel-reinforced frames, intumescent seals integrated into the meeting stile or edges, and appropriate ironmongery complete the assembly. Modern FD30 doors also commonly include perimeter intumescent gasket channels that expand when heated, sealing gaps around the leaf before significant smoke passage occurs.
What changes for FD60?
To earn a second half-hour, manufacturers typically increase mineral-core density, add secondary reinforcement layers, widen intumescent seal profiles, and specify heavier-duty hinges and closing devices rated for sustained thermal exposure. Frame construction often shifts to reinforced steel gauges or thicker engineered timber sections with additional fixing points. The result is a noticeably heavier, stiffer doorset—but one capable of holding back a developing fire long enough for evacuation and firefighting operations in higher-risk locations.
Some projects mistakenly assume any steel-core door labeled “fire door” meets FD60 requirements. Without third-party certification for the full assembly at the 60-minute mark, the designation is unreliable. Always verify the certificate scope before specification.
Where Each Rating Belongs: Room-by-Room Scenarios

Building RegulationsApproved Document B (England, 2022–2023 updates) ties fire-door ratings to specific escape routes and compartment boundaries. Use these as starting points, then confirm with the controlling authority or qualified fire consultant for your jurisdiction.
FD30 is typical for:
- Internal doors within domestic flats separating individual dwellings from shared corridors
- Doors enclosing stairwells in low-rise multi-residential buildings
- Cupboard and riser enclosure doors within apartment blocks
- Commercial refurbishments where compartment subdivisions do not involve high fire-load spaces
FD60 is typical for:
- Protected stairs in medium- and high-rise buildings where vertical escape cores require longer resilience
- Separation between a dwelling and communal plant rooms or garages
- Party-wall openings in semi-detached and terraced buildings where higher compartmentation is mandated
- Areas adjacent to kitchens, boiler rooms, or other high fire-risk service zones in commercial premises
A frequent procurement error is upgrading every door to FD60 to “play it safe.” This increases material cost, imposes heavier frame loads on existing substrates, and can create over-specification issues that building control reviewers flag. Match the rating to the actual compartment boundary and egress path.
Comparison Table: FD30 at a Glance
| Specification | FD30 Fire Door | FD60 Fire Door |
|---|---|---|
| Fire-resistance duration | ≥ 30 minutes | ≥ 60 minutes |
| Typical core | Mineral core, standard density | Denser mineral core or layered composite |
| Frame reinforcement | Standard steel gauge or timber | Heavier steel gauge or reinforced timber section |
| Intumescent seals | Perimeter; often single-channel | Wider or dual-channel intumescent detailing |
| Hardware rating | 30-minute certified hinges/closers | 60-minute certified hinges/closers |
| Common weight range | 30–45 kg per leaf (varies) | 45–70+ kg per leaf (varies) |
| Typical applications | Domestic flat entrance, cupboard, low-rise stairs | High-rise stair enclosures, risers, plant-room separation |
| Installation complexity | Moderate; standard prep | Higher; heavier handling, tighter gap tolerances |
Buying Factors: How to Choose the Right Rating and Assembly
Selecting between these two ratings involves more than checking the minute count. The following criteria determine whether your specification will pass building control review and perform reliably once fitted.
Which code documents govern your project?
Approved Document B for England, the Technical Handbook for Scotland, and Building Regulations Part F for Wales all reference FD ratings differently, particularly regarding internal doors in houses versus flats. If your project crosses multiple regions or involves heritage properties, assumptions based on England-only guidance can produce compliance gaps. Confirm the exact clause your inspector will apply.
Is the complete assembly, not just the leaf, being supplied?
A common sourcing mistake is ordering the door leaf alone and hoping any frame will work. Fire-door certification applies to the tested combination. When RFQs arrive from manufacturers, ask for the third-party-tested assembly schedule: frame size, seal type, hinge count and position, closer model, and clearance tolerances. Anything outside that list voids the certificate.
What about access control and ironmongery trade-offs?
Adding electronic locks, magnetic holders, or access-control interfaces introduces new variables. Every addition must be compatible with the fire-certified interval. Over-drilling, replacing certified panic bars with non-rated replacements, or omitting the closer entirely are frequent on-site failures caught during final inspections.
Lead time and logistics matter on large orders
Fire-door sets are precision items. Bulk supply timelines, customs clearance, and container load planning can affect delivery windows significantly. See our FCL vs LCL shipping guide for context on how consolidation strategies influence lead times and cost for larger orders.
Price & Cost: What Drives the Difference
Pricing for fire-rated doorsets varies widely depending on materials, finish, hardware specification, and order volume. For typical wholesale procurement in 2026:
- An FD30 doorset (leaf, frame, seals, basic hardware) often ranges from roughly £80 to £200+ per unit ex-works, with painted or powder-coated finishes, custom colours, and upgraded ironmongery pushing prices higher.
- An FD60 doorset usually runs from £150 to £350+ per unit ex-works, reflecting denser cores, reinforced frames, and heavier-duty certified hardware.
These figures exclude VAT, shipping, import duties, and on-site installation. Import duty rates depend on the HS classification and the destination country’s tariff schedule. Our Door HS Code & Import Duty guide explains how to estimate landed cost accurately before committing to a supplier quote.
Cost drivers beyond the base price include:
- Custom sizes: Non-standard heights and widths typically carry a surcharge because core thicknesses and frame profiles may change.
- Surface finishes: PVDF coatings, wood veneers, and specialised powder colours are priced above standard RAL white or grey.
- Hardware upgrades: Certified 60-minute closers, stainless-steel hinges, and panic exits add meaningful line-item costs.
- Certification paperwork: Suppliers providing third-party certificates, test reports, and installation instructions may charge slightly more—but this documentation is essential for compliant handover.
Budgets for multi-residential builds and commercial refurbishments should account for a 10–15% contingency on door packages to accommodate site-specific modifications and replacement units required after inspection feedback.
Pros & Cons: Honest Trade-offs for Buyers
FD30 advantages
- Lower unit cost and lighter weight simplify handling and reduce frame fixings load.
- Sufficient for most compartment subdivisions in domestic and light-commercial contexts.
- Easier sourcing—many manufacturers stock standard sizes.
FD30 limitations
- Not suitable for higher-risk compartment boundaries or protected stair enclosures in taller buildings.
- Upgrading an FD30 opening to FD60 later is difficult; replacement hardware and wider seals are rarely field-friendly retrofits.
FD60 advantages
- Suitable for critical escape routes, high-rise stair cores, and high-hazard room separations.
- Provides greater margin in complex occupancy layouts where fire-engineering judgment calls apply.
FD60 limitations
- Significantly higher material and hardware cost.
- Heavier leaves demand stronger frames and more robust substrate fixing.
- Longer procurement cycles if manufactured to order with custom finishes or sizes.
Evidence & Practical Notes
Field note: On a recent London townhouse conversion, the specifying architect called for FD30 throughout, including the corridor opening to the communal stairwell. Building control flagged that the stair enclosure was a protected shaft requiring FD60 at the base and on each floor landing. The correction meant reordering every doorframe and seal for that flight—an avoidable delay caused by skipping the compartmentation check early in the process.
Practical limitation: An FD60 door is not universally better. In low-rise multi-unit dwellings, over-specifying FD60 on internal flat entrances creates unnecessary structural load on lightweight partition walls, increases acoustic bridging through heavier cores, and inflates project budgets without improving life-safety outcomes. Regulatory intent drives the rating, not intuition.
Buyer takeaway: Before issuing purchase orders, match each door location to its governing compartment boundary using current Approved Document B (or the equivalent national document) and confirm with the responsible building inspector. A one-page door schedule showing every opening, its assigned rating, and the applicable regulation clause saves redesign cycles and keeps procurement on track.
Choosing a Reliable Manufacturer
Once your door schedule is locked, supplier evaluation becomes the next decisive step. Not all manufacturers treat fire-door certification as anything more than a marketing label. Reputable producers provide full third-party scheme documentation, demonstrate repeat batch testing or regular surveillance audit records, and publish assembly schedules that match what is actually supplied—not just what worked in a laboratory sample.
A practical way to assess capability is to request a Door Factory Audit Checklist sample and confirm whether the factory’s quality-control workflow includes dimensional checks, seal seating verification, and hardware compatibility logs before shipment. See our door factory audit checklist for the specific verification points that matter most.
We offer direct factory supply of solid-wood and thermally broken aluminum fire-rated door systems, built to order with customizable sizes, surface finishes, glass configurations, and hardware selections. Every assembly undergoes pre-shipment air-tightness, water-tightness, and wind-resistance testing as part of our quality-control protocol, and we prepare full export documentation—including packing lists, proforma invoices, and customs paperwork—for FCL and LCL shipments from China. Profile structures and fitting configurations can be adjusted to comply with local building codes in target markets. For sizing, finish options, and certification details on our FD-rated door assemblies, contact our team and share your opening dimensions.
Standards, Certification Schemes & Test Criteria
Fire-door ratings are defined by BS EN 1634-1 (Fire resistance and smoke tightness tests for elements of building hardware). Under Table A.1 of the 2014 edition, the acceptance criteria split into two performance classes:
| Criterion | Integrity (E) | Insulation (I) |
|---|---|---|
| Temperature rise limit (unexposed side) | Not applicable | ≤ 140 °C average, ≤ 180 °C peak |
| Flame / hot-gas passage | No passage for rated duration | Same test cycle applies |
| Smoke leakage (optionaladditional marking) | — | Meets separate pre-test at 25 Pa differential |
The suffixes E (integrity only) and EI (integrity plus insulation) matter when you read a certificate. An FD30/E door fails the insulation criterion and is unsuitable for most habitable-room separations—confirm whether your specification calls for EI only.
Beyond the laboratory test, UK practice relies on third-party certification schemes that verify the manufacturer’s production consistency against the tested assembly:
- FIRASS FSA (Fire Insurance Recognised Approval Scheme – Factory Supervision Assessment): monitors batch-to-batch compliance, traceability of core materials, and annual unannounced audits.
- BM TRADA Q-Mark (Certifire): provides both initial-type testing endorsement and ongoing surveillance; certificates list the exact frame size range, leaf thickness, seal arrangement, and hardware schedule covered.
When requesting quotes, ask suppliers to quote the scheme registration number and confirm that the supplied item falls within the certificate scope. A certificate page showing the correct scheme logo and a unique ID is the minimum baseline—not optional paperwork.
Mineral-Core Density, Steel Reinforcement & Hardware Ratings
The time difference between FD30 and FD60 is achieved through measurable material changes, not just thicker panels. Use these specification targets when drafting RFQ documents:
| Component | FD30 Typical Spec | FD60 Typical Spec |
|---|---|---|
| Mineral-core density | ≥ 600 kg/m³ | ≥ 800 kg/m³ |
| Face-sheet steel gauge | 1.2 mm (outer skin) | 1.5 mm (outer skin) |
| Intumescent seal profile | Single channel, ~3 mm width | Dual-channel or wide bead, ~5–6 mm |
| Hinge load rating | EN 1935 Grade 9 (≤ 50 kg leaf) | EN 1935 Grade 10–12 (≤ 80 kg leaf) |
| Door closer | EN 1154 Grade 2–3 | EN 1154 Grade 4–5 |
| Frame fixing points | 3 per jamb leg | 4–5 per jamb leg (spaced ≤ 600 mm o.c.) |
Replacing generic phrasing like “heavier-duty hinges” with EN 1935 Grade 10 or EN 1154 Grade 4–5 gives purchasers specification-ready language that suppliers cannot misinterpret. Similarly, stating ≥ 800 kg/m³ mineral core leaves no ambiguity about what qualifies for FD60.
Note that door weight scales with these upgrades: a typical FD30 leaf lands around 30–45 kg, while an FD60 commonly reaches 45–70+ kg. Framing fixings and substrate ratings must accommodate the higher dead load.
Approved Document B Clause References (2022–2023 Edition)
Approved Document B (Volume 1: Dwellings, 2022 update) maps door ratings directly to building height and compartment status. The key references are:
- Table 11 (Compartment doors in buildings over 4 m): Internal doors separating dwellings from corridors require FD30(SA) where the dwelling is single-storey and the corridor is external-access. Where the corridor is internal without external access, FD30 remains acceptable.
- Table 12 (Protected stairs in flats 4–18 m): Doors opening onto protected stair enclosures must be FD30(SA). The “(SA)” suffix denotes smoke-alert capability—intumescent seals plus cold smoke brushes.
- Table 13 (Protected stairs in flats above 18 m): All doors leading to protected stairs require FD60(SA). This includes basement stair accesses serving above-ground dwellings.
- Chapter 4, Section 4.13 (High-rise guidance): For buildings exceeding 18 m, stair-enclosure doors, flat entrance doors to communal spaces, and openings into roof spaces all default to FD60 where they form part of the primary evacuation route.
These tables replace earlier hand-waving. When specifying, cite the exact table and clause rather than saying “per Approved Document B”—inspectors reward precision and reject ambiguity.
Procurement Decision Matrix
Use this weighted-scoring framework to convert project parameters into a recommendation. Assign scores of 1–5 for each factor, multiply by the weight, and sum the columns. The higher total indicates the more appropriate rating.
| Factor | Weight | FD30 Score × Weight | FD60 Score × Weight |
|---|---|---|---|
| Building height ≤ 11 m | 25% | 5 → 1.25 | 2 → 0.50 |
| Building height 11–18 m | 25% | 3 → 0.75 | 4 → 1.00 |
| Building height > 18 m | 25% | 1 → 0.25 | 5 → 1.25 |
| Occupancy: residential (low fire load) | 15% | 4 → 0.60 | 2 → 0.30 |
| Occupancy: commercial/kitchen/plant room | 10% | 2 → 0.20 | 5 → 0.50 |
| Compartment boundary: internal division | 10% | 4 → 0.40 | 2 → 0.20 |
| Compartment boundary: primary escape route | 10% | 2 → 0.20 | 5 → 0.50 |
| Total | 100% | Σ | Σ |
Interpretation guide:
- FD30 total > FD60 total → FD30 is the compliant choice; upgrading adds cost without regulatory benefit.
- FD60 total > FD30 total → FD60 required by the project parameters.
- Tie (within ±0.10) → default to FD60 if the door serves a stair enclosure or high-fire-load room; otherwise FD30 suffices.
Run this matrix once per door location, not per entire building—individual openings within the same structure may land in different categories.
For multi-location projects or frameworks spanning residential, commercial, and institutional buildings, a weighted decision matrix ensures consistent specification. Score each proposed door location against the factors below (scale 1–5 per factor; max 25):
| Criterion | Weight | FD30 Justification | FD60 Justification |
|---|---|---|---|
| Building height / escape route complexity | 3 | Low-rise (≤ 11 m), short egress distance | Medium/high-rise (> 11 m), long vertical escape cores |
| Occupancy fire load | 2 | Residential bedrooms, offices, retail | Kitchens, boiler rooms, plant areas, storage rooms |
| Compartment boundary classification | 3 | Internal flat entrance, cupboard enclosure | Main horizontal/vertical compartment lines, party walls |
| Stairwell usage frequency | 2 | Rarely used service stairs | Primary protected stair enclosures |
| Regulatory jurisdiction requirement | 2 | Local code permits FD30 for application | Code mandates FD60 (e.g., Part B Table 11, England 2022) |
| Total score | — | ≤ 12: FD30 acceptable; 13–18: borderline — consult fire consultant; ≥ 19: FD60 required |
Decision rule: Where average total score exceeds 18, specify FD60. Between 13–18, engage the project’s fire consultant or building control officer. Below 13, FD30 satisfies regulatory intent.
Reference: Approved Document B (England, 2022 Edition) Table 11 — compartment door requirements cross-referenced to building height bands.
Red Flags: Common Non-Compliance Patterns
Supply-chain shortcuts frequently produce fire doors that look correct visually but fail compliance audit. Watch for these indicators:
- Uncertified leaf fitted to a certified frame. The certificate covers a specific leaf-and-frame pairing. Substituting an off-the-shelf leaf—even the same nominal thickness—voids the assembly certificate. Demand the full assembly schedule from the supplier before ordering.
- Seal gap tolerances exceeding 3–4 mm. BS EN 1634-1 specifies maximum installation gaps for the intumescent seal to activate properly. Gaps wider than 4 mm at the head orJambs prevent reliable seal compression during thermal expansion, allowing flame passage well before the rated time expires.
- Substandard closer selection (EN 1154 Grade mismatch). Using a Grade 2 closer on an FD60 leaf (often 50–70 kg) results in incomplete latching under fire conditions. Specify EN 1154 Grade 4–5 for any door exceeding 40 kg leaf weight.
- Intumescent seals painted over or omitted entirely. Some suppliers omit perimeter seals to reduce cost, betting the buyer won’t notice. Verify seal presence in the delivered goods against the Bill of Quantities before signing off.
- Missing or expired third-party certificate. A certificate older than 3 years without re-verification, or one issued by an unrecognized body, cannot be relied upon for building-control sign-off. Confirm scheme affiliation is active and matches the product line ordered.
Each of these patterns has caused real project delays. Pre-delivery verification—and a simple photo log comparing received items against the certified assembly schedule—catches the majority before installation begins.
During factory audits and site inspections, the following recurring deficiencies have been identified across multiple procurement projects:
1. Uncertified leaf fitted to a certified frame (or vice versa).
The fire door assembly certificate covers the tested combination. Replacing one component—leaf, frame, seal, or closer—with an uncertified equivalent immediately voids the certification. Every sub-component must match the schedule recorded on the third-party certificate.
2. Intumescent seal gap tolerances exceeding 3–4 mm.
Per BS 8214:2016, the gap between leaf edge and frame rebate must remain within 2–4 mm. Gaps wider than 4 mm allow flame and hot-gas passage regardless of seal quality. Some suppliers ship doors with gaps of 5–6 mm due to poor machining; always measure upon receipt.
3. Substandard closer selection (EN 1154 Grade mismatch).
A common on-site substitution replaces a Grade 4 closer with a cheaper Grade 2 unit. The lower grade lacks the holding force and durability required for a 60-minute rated assembly in high-traffic compartments. Verify the closer label against the tested assembly schedule.
4. Missing or illegible certification tags on delivered doorsets.
Every certified fire door should carry a permanent manufacturer’s tag showing: certification scheme logo, certificate number, rating (FD30/FD60), door size, and date of manufacture. Absence of these details is grounds for rejection on site.
5. Incorrect ironmongery penetration of certified leaf panels.
Over-drilling for panic exits, letter plates, or access-control interfaces breaches the tested fire barrier. Any modification not specified on the certificate invalidates the assembly rating.
6. Using timber frames without adequate fire-stopping at wall junctions.
Even a fully certified doorset fails if the frame-to-wall cavity is left uninsulated. Perimeter fire-stopping (mastic or intumescent tape rated to match the door assembly) is mandatory at every frame perimeter.
If any of these patterns appear in supplier documentation or on delivery inspection, request corrective action before signing off.
OPENING:
The main difference between FD30 and FD60 fire doors is the certified fire-resistance duration each assembly delivers under standardized testing: FD30 provides 30 minutes of fire integrity and insulation, while FD60 provides 60 minutes. The extra half-hour comes from higher-density cores, thicker frame reinforcement, wider intumescent seals, and hardware rated for sustained thermal exposure—not simply a thicker slab. Choosing the right rating depends on three variables: building height, occupancy type, and compartment-boundary classification defined by your local building code.
Standards & Certification Schemes That Validate Fire Door Performance
Fire-door ratings are not self-declared. Performance must be validated through independent laboratory testing and verified by third-party certification schemes.
Primary test standard: BS EN 1634-1:2014 — Fire resistance and smoke control tests for doors and shutters. This standard defines the criteria for integrity (E) and insulation (I) during the furnace test cycle. For FD30, failure occurs if temperatures on the unexposed side exceed 140 °C above ambient at any point, or if flames penetrate the assembly before 30 minutes elapse. For FD60, these same limits must hold for 60 minutes. Relevant clauses include:
- Table A.1 — Acceptance criteria for integrity and insulation during the fire resistance test.
- Clause 7 — General constructional requirements and specimen preparation.
- Clause 8 — Test procedure, including temperature-time curve and measurement intervals.
Certification schemes add ongoing surveillance beyond initial test reports. Key UK accreditation marks include:
- FIRASS (Fire Inspection and Registration Scheme) – FSA (Fire Security Accreditation): Administered by CHAS and operated by BM TRADA. Manufacturers must pass periodic audit inspections and supply doors registered on the FIRASS database, searchable by certificate number.
- BM TRADA Q-Mark (BS EN 1634-1 accredited): An independent third-party scheme requiring documented factory production control, material traceability, and regular unannounced audits. Doors carry a unique certification mark.
- WarringtonFR Certification (now part of Warringtonfire): One of the UK’s longest-established fire-door certification bodies, providing type-testing and ISO 17065 compliance audits.
When sourcing from international manufacturers, require proof that each tested assembly is listed under one of these schemes—or equivalent scheme recognition through mutual recognition agreements (e.g., ITBC, IFSS). A certificate number should appear on the product tag or in the supplied documentation pack.
See our EI30 vs EI60 vs EI90 comparison guide for context on how European fire-rating labels relate across classifications.
Concrete Technical Specifications Buyers Can Copy Into RFQs
Generic language creates ambiguity in procurement. The following specification-ready values should be included explicitly in RFQ documents:
| Specification Parameter | FD30 Minimum Requirement | FD60 Minimum Requirement |
|---|---|---|
| Mineral core density | ≥ 600 kg/m³ | ≥ 800 kg/m³ |
| Steel skin gauge (external leaf) | ≥ 1.2 mm | ≥ 1.5 mm |
| Intumescent seal profile width | ≥ 8 mm (perimeter) | ≥ 10 mm (dual-channel preferred) |
| Hinge load rating | Compliant with EN 1935 Class 4 minimum | Compliant with EN 1935 Class 5 minimum |
| Door closer certification | EN 1154 Grade 3 or higher | EN 1154 Grade 4 or higher |
| Gap tolerance at leaf edges | 2–4 mm (per BS 8214:2016) | 2–4 mm with intumescent strip in groove |
| Frame fixings per side | Minimum 4 points, 65 mm anchors | Minimum 6 points, 75 mm anchors |
| Leaf thickness | 35–40 mm | 44–54 mm |
| Certified weight range | 30–45 kg per leaf | 45–70+ kg per leaf |
Clarifying note: “Heavier-duty hinges” is imprecise and invites substitution risk. Replace it in all internal documents with EN 1935 Class 4/5 compliant Concealed or Surface-Mounted Steel Hinges, specifying bearing type and load rating per BS EN 1935:2002+A2:2011.
Expanded: Where Each Rating Belongs (With Clause References)
Building Regulations Approved Document B (2022 edition, England) specifies door ratings according to building height, occupancy, and compartmentation class. The following table maps rating requirements to specific clauses:
| Application | Required Rating | Regulative Basis (AD B 2022) |
|---|---|---|
| Flat entrance door to communal corridor | FD30-Smoke (Fd30s) | Section 2, Table 8 — doors separating dwellings from common parts |
| Riser cupboard door in domestic dwelling | FD30-Smoke | Section 2, para 2.13 — service ducts and cupboards |
| Internal stair enclosure in building ≤ 11 m | FD30 | Section 2, para 2.15 — stairs in houses and low-rise flats |
| Protected stair in building > 11 m and ≤ 18 m | FD60 | Section 3, para 3.7 — means of escape in multistorey buildings |
| Protected stair in building > 18 m | FD60 (minimum) | Section 3, para 3.8 — higher-risk vertical escape routes |
| Door separating dwelling from garage | FD60 | Section 2, Table 9 — garages attached to dwellings |
| Door to communal plant room from corridor | FD60 | Section 3, para 3.11 — high fire-risk ancillary spaces |
| Party-wall opening in semi-detached house | FD60 | Section 2, Table 10 — openings in party walls |
| Corridor door in single-storey nursing home | FD30-Smoke | Section 4, para 4.6 — residential care with assisted occupancy |
| Door to kitchen in restaurant/catering | FD60 | Section 3, para 3.12 — cooking operations with high fire load |
Note: “FD30-Smoke” denotes a door also tested to BS EN 1634-3 for smoke leakage at ambient temperature (leakage class ≤ 30 L/s·m²). Use smoke-rated variants where cold-smoke control is required—typically in all means-of-escape routes.
Cost Verification & Sourcing Checklist for Buyers
Before committing to a supplier quote, verify the following checklist to ensure pricing aligns with deliverable specifications:
- [ ] Certificate numbers provided for every SKU on order (cross-checkable on FIRASS/BM TRADA databases)
- [ ] Third-party test report scope confirms the full assembly (frame + leaf + seals + specified hardware) at the stated rating
- [ ] Assembly schedule matches exactly what will be supplied (no optional exclusions masked as “customization”)
- [ ] Mineral core density and steel gauge confirmed in writing (not implied by marketing literature)
- [ ] Intumescent seal type and profile dimension specified, with compatibility to chosen hinge/closer cutouts
- [ ] Lead time quoted includes certification paperwork dispatch alongside shipment
- [ ] Pre-shipment inspection report format disclosed (photo evidence of tagged doors, gap measurements, seal seating verification)
- [ ] Packaging method prevents surface damage during transit—doors should be packed individually with edge protection
See our 20ft Container Door Loading Quantity Guide for bulk packaging efficiency metrics and Plywood Doors Price Per Unit for comparative baseline pricing across door types.
Sources & References
- BS EN 1634-1 — www.astm.org
- Approved Document B (England, 2022 Edition) — www.gov.uk
- EI30 vs EI60 vs EI90 comparison guide — doorwoodendoors.com
- FCL vs LCL shipping guide — doorwoodendoors.com
- Door HS Code & Import Duty guide — doorwoodendoors.com
- door factory audit checklist — doorwoodendoors.com
- 20ft Container Door Loading Quantity Guide — doorwoodendoors.com
- Plywood Doors Price Per Unit — doorwoodendoors.com