Soundproof Doors: Acoustic Door Solutions for Commercial & Residential Projects

Acoustic Door Solutions

Soundproof Doors: Acoustic Door Solutions for Commercial & Residential Projects

Lab-tested acoustic doors rated STC 30 to STC 52. Engineered systems with automatic seals, acoustic thresholds, and certified performance data.
✓ ISO 9001:2015 Certified✓ ASTM E90 Lab Tested✓ STC 30-52 Range✓ Combined Fire + Acoustic✓ UL/CE Dual-Certified✓ 20+ Years
The Problem

Why Standard Doors Fail at Sound Isolation

A standard hollow-core door provides STC 20-25. True soundproofing requires an engineered system: high-mass core, perimeter acoustic seals, automatic bottom seal, and sealed frame-to-wall connections. Jusen engineers each element to hold its rated performance.

STC Ratings

Understanding STC Ratings

STC RatingPerformance LevelTypical Application
STC 25-30BasicStandard interior doors
STC 30-35ModerateResidential bedrooms
STC 35-40GoodHotel guest rooms
STC 40-45Very GoodHotel corridors, conference rooms
STC 45-50ExcellentRecording studios, luxury suites
STC 50+ProfessionalBroadcast facilities, music studios
OITC Ratings

STC vs. OITC: Why One Number Is Not Enough

STC (Sound Transmission Class, ASTM E90 / E413) measures isolation of mid- and high-frequency sound - conversation, television, music. It does not capture low-frequency energy such as road traffic, aircraft, HVAC plant, bass from music venues or elevator machinery. For those sources, specifiers use OITC (Outdoor-Indoor Transmission Class, ASTM E1332), which weights the 80-4000 Hz range toward low frequencies.

Because OITC emphasizes low-frequency performance, a door can rate STC 45 yet only OITC 30. Whenever the noise source is traffic, rail, aviation or mechanical plant - the most common complaints in hotels, apartments and offices - specify OITC, not STC alone.

RatingStandardFrequency FocusBest For
STCASTM E90 / E413Mid-high (speech, TV)Offices, conference rooms, residences
OITCASTM E1332Low-mid (traffic, aircraft, machinery)Street-facing facades, airports, plant rooms, music venues
RwISO 10140 / ISO 717Mid-high (European equivalent)EU / international specifications
Testing & Certification

How Acoustic Door Performance Is Measured

Every JuSen acoustic door model is tested by an independent, accredited laboratory. An acoustic rating is meaningless without the test standard behind it - here is what we certify to:

ASTM E90Laboratory measurement of airborne sound transmission loss - the basis of STC.
ASTM E413Classification of the transmission-loss curve into a single STC number.
ASTM E1332Outdoor-Indoor Transmission Class (OITC) for low-frequency noise.
ISO 10140International acoustic laboratory test method; ISO 717 yields Rw.
UL 10C / NFPA 252Fire test for door assemblies; combined fire-and-acoustic ratings.
ISO 9001:2015Quality management system covering the full manufacturing process.
Performance Data

Transmission Loss by Frequency

Sound transmission loss (TL) varies by frequency. The table below shows representative third-octave band performance for our standard acoustic door constructions; confirm exact figures against the test report for your specified model.

Construction125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 HzSTC
STC 32 door23263136394232
STC 40 door28323844474940
STC 45 door31364349525445
STC 52 door35414955586052
Specifications

Door Construction vs. STC Performance

Acoustic performance is driven by mass, stiffness and airtight sealing. Use the table below as a first-pass selector before confirming details with our engineering team.

ConstructionLeaf ThicknessCoreTypical STCTypical Weight
Solid-core wood1-3/4 in (44 mm)Particleboard / mineralSTC 30-36~45-60 kg
Acoustic wood / veneer2-1/4 in (57 mm)High-density mineral + mass layerSTC 40-46~75-95 kg
Acoustic steel1-3/4 in (44 mm)Insulated steel + dampingSTC 40-50~65-90 kg
Double-leaf assembly2 x 1-3/4 inAir gap + perimeter sealsSTC 48-52+~120-160 kg
Engineering

How Our Acoustic Doors Are Engineered

Acoustic Door Assembly — Vertical Section Wall Wall High-Mass Core Acoustic Threshold 1 · High-Mass Core 2 · Perimeter Acoustic Seal 3 · Frame-to-Wall Sealed (Caulk) 4 · Automatic Drop Seal 5 · Acoustic Threshold (sill)
Figure 1 — An acoustic door is an engineered system: mass in the leaf, seals at every gap, and a sealed frame-to-wall connection.

High-Mass Core Construction

High-density particleboard, mineral-filled composite, or laminated timber. Acoustic door weights range from 60-120 kg.

Perimeter Acoustic Seals

Compression gaskets around all four edges. Even a 1mm gap can reduce STC by 10 points.

Automatic Bottom Seals

Drop-down seals that create an airtight barrier at the threshold. Essential for STC 40+.

Heavy-Duty Ball-Bearing Hinges

Ball-bearing hinges rated for 100+ kg ensure smooth operation and maintain seal alignment.

Acoustic Thresholds

Tight seal at the bottom without impeding wheelchair access. ADA-compliant options.

Sealed Frame-to-Wall Connection

Acoustic caulk prevents flanking sound transmission. Installation instructions specify sealant types.

Fire + Acoustic

Combined Fire-Rated Acoustic Door Assemblies

Many sound-isolation locations - stairwells, plant rooms, hotel corridors, mechanical floors - also require a fire rating. Our acoustic doors can be supplied as combined fire-and-acoustic assemblies, tested to both acoustic and fire standards without sacrificing either performance.

Fire ratings20 / 45 / 60 / 90 minute (UL 10C / NFPA 252)
Acoustic rangeSTC 35-52, OITC 30-42 (combined)
SealsIntumescent + acoustic perimeter seal system
HardwareFire-rated hinges, closers and latches as standard
Applications

Acoustic Door Applications by Industry

Hotels & Hospitality

Guest room doors STC 35-40, corridor doors STC 40-45, ballroom partitions STC 48-52.

Office & Commercial

Executive offices STC 40-45, medical and legal offices STC 45+ for confidentiality.

Residential

Home theaters, music rooms, and work-from-home spaces benefit from STC 35-45 doors.

Recording Studios & Venues

Professional audio environments require STC 50+ double-door assemblies.

Product Range

Acoustic Door Product Range

Wood Veneer Acoustic Doors

Wood Veneer Acoustic Doors

Walnut, oak, mahogany, custom veneers. STC 35-48.

Painted Flush Acoustic Doors

Painted Flush Acoustic Doors

Any RAL/Pantone color. STC 35-45.

Steel Acoustic Doors

Steel Acoustic Doors

Heavy-gauge steel. STC 40-52.

Double-Leaf Acoustic Assemblies

Double-Leaf Acoustic Assemblies

Paired doors with air gap. STC 48-52.

Door Types

Acoustic Door Type Comparison

Door TypeBest ForMax STCNotes
Single swingOffices, hotel guest roomsSTC 50Simplest, lowest cost
Double leafCorridors, studios, plant roomsSTC 52+Best high-performance option
Sliding acousticPartitions, space-savingSTC 40-45Sealing more critical
Glazed acousticVisual connection + isolationSTC 35-42Glass reduces rating ~3-5 pts
Cost Factors

What Determines Acoustic Door Cost

01

STC / OITC Rating

Higher ratings demand denser cores, better seals and heavier construction - the single largest cost driver.

02

Fire Rating

Combined fire-and-acoustic assemblies add intumescent seals and fire-rated hardware.

03

Size & Configuration

Oversized, double-leaf or glazed doors increase material and hardware cost.

04

Finish & Hardware

Wood veneer, stainless cladding, automatic operators and access control add cost.

05

Quantity

Bulk and project orders benefit from factory-direct pricing and lower unit cost.

06

Certification

Independent lab testing per model and region adds documentation cost but de-risks the spec.

Installation

Installation & Sealing: The Weakest-Link Principle

An acoustic door is only as good as its weakest path. A door rated STC 45 can perform at STC 30-35 if installed poorly - a 3 mm gap around the perimeter can drop performance by 10 points or more. Our engineered approach controls every leak path:

Perimeter acoustic seals

Compression gaskets on the head and jambs close the frame-to-leaf gap.

Automatic drop seal

A concealed bottom seal drops on closing to seal the threshold gap.

Acoustic threshold

Recessed or surface thresholds mate with the drop seal for a continuous barrier.

Sealed frame-to-wall

Acoustic caulk and backer rod close the frame-to-wall cavity to stop flanking.

We ship each assembly with a written installation and sealing guide, and our engineers support site teams on high-STC and fire-rated projects.

Client Voices

What Our Clients Say

“We field-tested Jusen's STC 45 doors and they exceeded the lab rating by 2 points.”
Acoustic ConsultantInternational Hotel
“Our recording studio needed STC 52 doors. Jusen achieved STC 53 in independent testing.”
Studio DesignerAudio Facility
“The combined fire-acoustic doors passed both UL fire and ASTM E90 acoustic tests on first submission.”
Fire Safety EngineerHigh-Rise
FAQ

Frequently Asked Questions

What is the difference between STC and Rw ratings?
STC is US/Canadian (ASTM E90). Rw is European (ISO 10140). Roughly Rw ≈ STC - 2 to 3 points.
Can I upgrade an existing door to improve its STC rating?
Adding seals gives +5-8 STC. Achieving STC 40+ usually requires a purpose-built acoustic door.
Do you provide lab test reports?
Yes, every model is tested by an independent accredited lab per ASTM E90 and/or ISO 10140.
What is the MOQ for acoustic doors?
Standard models (STC 35-45): 50 units. High-performance (STC 48-52): 20 units.
How important is installation quality?
Critical. A poorly installed STC 45 door performs at STC 30-35. We provide detailed guides.
Can acoustic doors include glass panels?
Yes, but glass reduces STC by 3-5 points. We engineer acoustic glazing rebates.
What is OITC and when should I specify it?
OITC (Outdoor-Indoor Transmission Class, ASTM E1332) measures low-frequency isolation from traffic, aircraft and machinery. Specify OITC for street-facing facades, airports, plant rooms and music venues where low-frequency noise dominates.
Browse Products

Related Product Categories

Each solution maps to specific product lines — follow a category to view specifications, available configurations and factory-direct pricing.

20+
Years Manufacturing
Since 2006
150+
Skilled Employees
In-house production team
150k+
Units Per Year
150,000–200,000 sets
60+
Export Markets
Across five continents
Get In Touch

Need Acoustic Doors for Your Project?

Tell us your STC requirements, application, and quantity. Receive a technical proposal within 48 hours.

Scroll to Top
Chat on WhatsApp Send Inquiry